Abstract
This research includes the design of feeding and sewage pipes
design and of the septic tank for a multi-storey building consisting of
nine floors and a ground floor in the city of Omdurman (AlThawra),
where the consumption rate of the building was calculated by three
different methods.
The building was divided into three lines to feed the building. The
diameters of the vertical pipes (2_1.75) inch equivalent to(50.8- 44.45)
mm and the horizontal (1.5_0.5) inch equivalent to (38.1-12.7)mm
were calculated according to the methods used according to the second
method, which depends on the slope of the hydraulic pressure line and
the feeding rate of the devices and the calculation of the diameters of
the vertical liquid waste pipes (3 inch) equivalent to(76.2)mm. and
horizontal (4 inch) equivalent to(101.6)mm in addition to the design of
the septic tank (4.5*2*2)m